Wiring Aac Disconnect
Strip about 1 2 inch of insulation from the ends of the wires inside the disconnect box.
Wiring aac disconnect. Make sure you use the proper size disconnect. Wiring an a c unit involves installing a double pole 240 volt circuit breaker in the main service panel running a 240 volt cable to the a c s location installing a safety disconnect switch there and then running weatherproof flex from the switch to the a c s terminal box. Step 2 prepare to wire the disconnect switch. The electrical wiring to the disconnect is fed from the load side or outgoing side of the electric meter.
Wiring a disconnect box to mini split disconnect boxes are simple to wire up with power coming in and going out. The side of the meter that receives incoming power from the utility service lines is called the line side. A separate disconnect such as the utility required ac disconnect or a backfed circuit breaker in a panel board provided that it meets the location requirements of 690 14 c 1 nec 2011 690 13 a nec 2014 since the additional disconnecting means must be located in a readily accessible location a rooftop mounted disconnect. There are two hot wires and a neutral wire.
If the current draw is 28 amps you will need a disconnect rated for 30 amps. How to wire a disconnect. Install the wires to the condensing unit. Depending on whether you have a 110v or 220v circuit you will have either 3 or 4 wires.
One will ground a bare copper or green wire one will be neutral a white wire and one or two will be hot wires black or a combination of black and red. Pull the wire through the conduit while leaving enough on each end to make the connections. With the breaker turned off the wires can be disconnected and the cable removed from the e lectrical compartment of the. Cut enough conduit to reach from the disconnect box to the wiring panel on the air conditioning condensing unit.
The line side is the cable supplying voltage from your electrical panel. If the current draw is 48 amps you will need a disconnect rated for 60 amps. The hot wires each carry 120 volts and are different phases. If the disconnect is added to an existing ac unit it should be within reach of the already existing cable so only a short cable is needed to bridge the switch to the ac unit.