Red Jacket Control Box Wiring Diagram
The standard control box interfaces between the fuel dispenser and the turbine pump and has an indicator light that signals when a customer begins fueling.
Red jacket control box wiring diagram. Inspect the control box s wiring diagram located on the back of the lid. While viewing the wiring diagram figure 1 or inside the enclosure lid connect the input power l1 and l2 wires to the terminal block labeled tb1. This control box is designed to operate from 200 to 250vac. Red jacket s iq control box raises the standard for typical relay control boxes.
Newly designed features of the red jacket stp are. The units are designed to operate continuousl y at or above minimum flow rate or with an intermittent duty cycle not to exceed 20 on off cycles per hour. All 3 wire submersible pumps from 1 3 up to 1 hp utilize a qd control box to start the pump. The red jacket dealer said the replacement centripro would replace the orginal.
Optimize your fuel flow dispensing needs setting the standard for high throughput high reliability fueling. Red jacket 1 2 hp 208 230 volt 60hz 11h 7 2a code l 50n1 3450 rpm pt 179 314 3 wire there s no control box in the garage where the wires terminate. If there was one it was cut out. Kg 50c201 5 115 11 0 279 19 2 8 7 50c211 2 wire 5 230 11 0 279 19 2 8 7 75c211 psc.
Service spill elimination. In this video chris shows you how to wire the franklin electric qd control box. Red jacket 2 hp stp fixed speed conversion kit. The wires from the pressure switch connect to the electrical input terminals usually called l1 and l2 the wires heading to the well s pump motor connect to terminals with a start run.
Three phase motors require a magnetic starter with class 10 overload protection. The red jacket submersible turbine pump stp is engineered for advanced environmental protection serviceability safety and flow. Centripro 4 single phase motors red jacket type hp volts length weight no. The red jacket standard control box is the simplest way to control site fueling.
Never wire a submersible pump to run continuously at less than minimum flow rate. The wiring diagram identifies the electrical terminals and lists their functions. I need to find a diagram or person who knows what sorta cap i m going to need when building my own control box. The red jacket stp fits 4 inch npt threaded thin wall risers and is available in a wide variety of horsepowers.
Control box is required with 3 wire single phase units. Red jacket line leak detection systems do not function if the submersible pump runs continuously. The wires are the same as the orginal red jacket and we wanted to check to see if there was a compatible issue with the new box before we pulled the pump.