How To Wire A Smoke Detector Wiring Diagram
Wiring diagrams are included in the instructions supplied with all alarms but here are a few basics.
How to wire a smoke detector wiring diagram. How to install a hardwired smoke alarm ac power and alarm wiring intended for how to wire smoke detectors in series diagram image size 715 x 365 px. For details on how to do this see connecting 4 wire smoke detectors. The black wire on the detector is also connected to the black wire on the service panel. Locate the junction box and turn off power.
Mains powered smoke heat alarms radiolink radiolink and smartlink wireless interconnection. The main supply is 120v ac in us and 230v ac in eu. Join the black circuit wire s to the black wire lead on the smoke detector. A standard wiring junction box to a 4 inch 10 cm size on either the ceiling or wall.
In our basic wiring diagram a single or multiple heat and smoke detectors are installed in the home by connecting the live line or hot neutral ground and an interconnected wire to the alarm. In order to connect more smoke detectors for multi level homes or building use three wire cables. All mains powered alarms and accessories need a mains supply that is taken from a permanent live feed for example a lighting circuit. Basic electricians pouch of hand tools non metal step ladder and a voltage tester.
The connections are to be secured using multipurpose wiring tools. A smoke or heat detector can be installed to the existing or new home wiring. If you are using a metal box also attach a bare copper or green insulated pigtail wire to the box. This allows you to locate the end of line resistor and power supervision relay at the alarm panel.
Connect the white circuit wire s with the white wire lead on the smoke detector. To begin turn off power at the junction box and connect the alarm to the building s electrical wiring. The white wire on the detector is connected to the white wire on the service panel box. To install the smoke detectors connect a two wire cable from the service panel to the first smoke detector.
Truly we have been realized that how to wire smoke detectors in series diagram is being just about the most popular topic at this time. Simple steps to smoke detector battery replacement. 12 3 nmb and ground wire. Connect all bare copper ground wires together.
The extra run of 4 conductor wire gives us a return path to the panel. Proper alarm location and placement see alarm placement guidelines connect the alarm to 120v wiring.