Ge Shunt Trip Wiring Diagram
A wiring diagram is a streamlined traditional pictorial representation of an electrical circuit.
Ge shunt trip wiring diagram. Find out here ge shunt trip breaker wiring diagram sample collection of ge shunt trip breaker wiring diagram. It shows the elements of the circuit as streamlined forms and the power as well as signal connections between the devices. As you know that electricity is dangerous but it s become more dangerous when it s upgrade from the 220 volts to 3 phase 440 volts. Shunt trip accessories in qo b are factory installed only and can not be added to an existing breaker.
There will be one wire for the 120v ac one wire for the operation of the shunt trip and one wire for the auxiliary contact. Shunt trip circuit breakers can be used to automatically disconnect a install the breaker in the panel and wire up the three phases to the three. A wiring diagram is a simplified traditional pictorial depiction of an electric circuit. Need direction to wire a ge tqsta1 shunt trip breaker for anselll system.
It shows the elements of the circuit as simplified shapes as well as the power as well as signal connections in between the gadgets. Undervoltage release uvr the undervoltage release opens the circuit breaker when its supply. Shunt trip breaker wiring diagram this post is about the single wiring diagram of mccb shunt trip breaker. The accessory terminals will accept 2 14 12 al cu.
Electrically from a remote location by application of control voltage to the accessory leads. It reveals the elements of the circuit as simplified forms as well as the power and signal connections in between the gadgets. Shunt trip st the shunt trip opens the circuit breaker when its coil is energized by a voltage input see table 1. These wires should be wired to terminals on the remote operator control station.
Of the wiring diagram energizes the coil of the. Wire the remote control elements to the remote operator station. The shunt trip has coil clearing contacts that open when the voltage is applied so either momentary or maintained contacts can be used to initiate voltage. Shunt tr electrical specifications.
In the diagram a mccb molded case circuit breaker shown which is wired for 3 phase system. The shunt trip allows the circuit breaker to be tripped table i. Which is also known with the name of kill switch. Shunt trip breaker wiring diagram which related with safety and protection of electricity.
Shunt trip device black wires maximum permissible voltage is 110 of rated for ac 125 for dc. Assortment of ge shunt trip breaker wiring diagram. Run wire from the breaker panel terminals to the operator control panel. Variety of ge shunt trip breaker wiring diagram.
The breaker shunt trip coil is controlled by the emergency switch. Ge shunt trip breaker wiring diagram. It is supplied with yellow and white secondary leads connected to a secondary connector plug see figure 2.